Shenzhen K-Easy Electrical Automation Company Limited

Energy efficient, beautiful environment

Manufacturer from China
Active Member
3 Years
Home / Products / Variable Frequency Inverter /

3 Phase VFD Variable Frequency Drive Inverter 0.75KW Multi Function

Contact Now
Shenzhen K-Easy Electrical Automation Company Limited
City:shenzhen
Country/Region:china
Contact Person:MrsCandy Liu
Contact Now

3 Phase VFD Variable Frequency Drive Inverter 0.75KW Multi Function

Ask Latest Price
Video Channel
Brand Name :K-Drive
Model Number :KD600
Certification :CE And ISO Certificated
Place of Origin :China
MOQ :1pcs
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :30000 Sets Per Month
Delivery Time :1~7days
Packaging Details :Carton Box /Woody Box
Product Name :3HP 5HP 7HP 10HP 15HP AC Drive
Control Mode :V/F, SVC, VC, Torque Control
Size :Depend Model
Weight :Depend Model
Frequency :50Hz/60Hz
Input Type :Single Phase / Three Phase
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

K-DRIVE Miniature Low Frequency Inverter 0.75kw VFD 220V 3 Phase Frequency Converter 60hz 50hz

Product Details

3HP 5HP 7HP 10HP 15HP AC Drive Frequency Inverter VFD For Asynchronous Motor

High torque in low speed, fast response
Load capacity in low speed
VF: 180%@0.50Hz
SVC: 180%@0.25Hz
VC: 200%@0.00Hz
Load 0%->100%@50HZ
Load 100%->0%@50HZ
Rapid response to impact loads
Powerful internal logic
1,Built-in up to 6 sets of delay functions, awide variety of input sources, the output can be used as a variety of other built-in module inputs.
2,Built-in up to 4 sets of comparator units, any input, multiple comparison functions, the output can be used as a variety of other built in module inputs.
3,Built-in up to 4 sets of logic units, arbitrary inputs, multiple logic operations, and outputs can be used as inputs for various other built in modules.
4,The above modules can be used alone or in combination to achieve complex internal logic functions to meet various applications, saving
peripheral equipment and wiring

High performance

1. More Accurate Motor Autotuning
2. Advanced open and close loop vector control
3. Perfect voltage and current control, reducing the fault protection times
4 Multiple braking modes and instant stopping
5. 0.75kW~7100kW(Three Phase 400V)


Models and Specifications

ACDrive Model Rated lnput
Current
Rated Output
Current
Adapting motor Dimensions(mm) Gross
Weight(kg)
(A) (A) (kw) H(mm) W(mm)
220V (-15%~ 20%)single Phase Input & Three Phase Output
KD600-2s-0.4GB 5.4 2.3 0.4 148 74 130 1.45
KD600-2s-0.75GB 8.2 4 0.75 1.45
KD600-2S-1.5GB 14 7 1.5 165 86 140 1.45
KD600-2s-2.2GB 23 9.6 2.2 2.2
KD600-28-4.0GB 20.5 17 4 234 123 176 2.7
KD600-2S-5.5GB 26 25 11 275 160 186 5.5
KD600-2s-7.5GB 35 32 15 5.5
KD600-2s-11GB 46.5 45 2m2 330 189 186 7
KD600-28-15GB 62 6o 30 425 255 206 15
380V 480V (-15%-20%) Three Phase lnput & Three Phase output
KD600-4T-0.75GB/1.5PB 3.4 2.1 0.75 165 86 140 1.45
KD600-4T-1.5GB/2.2PB 5.0/5.8 3.8/5.1 1.512.2 1.45
KD600-4T-2.2GB/4.OPB 5.8/10.5 5.1/9.0 2.2/4.0 1.45
KD600-4T-4.OGB/5.5PB 10.5/14.6 9.0/13.0 4.0/5.5 192 110 165 2.15
KD600-4T-5.5GB/7.5PB 14.6/20.5 13.0/17.0 5.5/7.5 2.15
KD600-4T-7.5GB/11PB 20.5/22.0 17.0/20.0 7.5/9.0 234 123 176 2.7
KD600-4T011GB/15PB 26.0/35.0 25.0/32.0 11.0/15.0 275 160 186 5.05
KD600-4T015GB/18PB 35.0/38.5 32.0/37.0 15.0/18.5 5.05
KD600-4T18GB/22PB 38.5146.5 37.0/45.0 18.5/22.0 330 189 186 6.95
KD600-4T-22GB/30PB 46.5/62.0 45.0/60.0 22.0/30.0 6.95
KD600-4T-30G(B/37P(B) 62.076.0 60.0/75.0 30.037.0 425 255 206 14.15
KD600-4T-37G(By45P(B) 76.0/92.0 75.0/90.0 37.0/45.0 14.15
KD600-4T-45G(By55P(B) 92.0/113.0 90.0/110.0 45.055.0 534 310 258 26.55
KD600-4T-55G(B)75P(B) 113.0/157.0 110.0/152.0 55.0/75.0 26.55
KD600-4T-75G(By93P(B) 167.0/180.0 152.0/176.0 75.0/93.0 560 350 268 40
KD600-4T-93G/110P 180.0/214.0 176.0/210.0 93.01110.0 40.5
KD600-4T-110G/132p 214.0/256.0 210.0/253.0 110.0/132.0 695 410 295 56.5
KD600-4T-132G/16oP 256.0/307.0 253.0/304.0 132.0/160.0 60
KD600-4T-160G/185P 307.01345.0 304.0/340.0 160.0/185.0 1050 480 330 108
KD600-4T-185G/20OP 345.0/385.0 340.0/380.0 185.0/200.0 112
KD600-4T-200G/220P 385.0/430.0 380.0/426.0 200.0/220.0 120.5
KD600-4T-220G/250P 430.0/468.0 426.0/465.0 220.0/250.0 1200 590 365 122
KD600-4T-250G/280P 468.0525.0 465.0/520.0 250.0/280.0 130
KD600-4T-280G/315P 525.0590.0 520.0/585.0 280.0/315.0 153
KD600-4T-315G/355P 590.0/665.0 585.0/650.0 315.0/355.0 1290 700 400 190
KD600-4T-355G/40OP 665.0/785.0 650.0/725.0 355.01400.0 195
KD600-4T-400G/450P 785.0/883.0 725.0/820.0 400.0/450.0 198
KD600-4T-450G/500P 883.0/920.0 820.0/900.0 450.0150o0.0 1800 1000 500 318
KD600-4T-500G/550P 920.0/1020.0 900.0/1000.0 500.01550.0 320
KD600-4T-550G/630P 1020.0/1120.0 1000.0/1100.0 550.0/630.0 324
KD600-4T-630G 1120 1100 630 330
KD600-4T-710G 1315 1250 710 2200 1200 600 434

Customer visit

3 Phase VFD Variable Frequency Drive Inverter 0.75KW Multi Function


3 Phase VFD Variable Frequency Drive Inverter 0.75KW Multi Function


K-Drive VS Other brands

Performance Common brands K-Drive
Applicable motors Asynchronous motors Asynchronous /synchronous motors
Starting torque 2.0Hz, 150% (sensor-less vector control) 0Hz, 180% (closed-loop vector control) 0.5Hz, 180% (sensor-less vector control) 0Hz, 200% (closed-loop vector control)
Speed adjustable range 1:100 (SVC), 1:1000 (VC) 1:200 (SVC), 1:1000 (VC)
Ambient temperature (no derating required) -10-40ºC -10-50ºC (for most of the models)
Rated input voltage 208VAC-400VAC 208VAC-480VAC
Communication Modbus RTU//ASCII Modbus RTU//ASCII Profibus-DP, CANopen, etc.
Position control (fixed length, or angular positioning) ×
Field weakening control ×
Autotune online Online Online & Offline
Short-time ramp-up Trip No trip
Customized features (software and/or hardware) Unprocurable or no experience Procurable with rich experience

How to maintenance your variable frequency drivers(vfd)

VFDs (Variable Frequency Drives) are used to control the speed and torque of AC electric motors. Proper maintenance of VFDs is important for their longevity and performance. Here are some steps you can take to maintain your VFD:

  1. Keep it clean: Regularly clean the VFD and the surrounding area to prevent dust and debris from entering the unit.

  2. Check for loose connections: Inspect the connections to ensure they are tight and secure. Loose connections can lead to overheating and damage to the VFD.

  3. Check for overheating: Use a temperature gun to check for any hot spots on the VFD. Overheating can be caused by excessive dust buildup, loose connections, or other issues.

  4. Check for proper ventilation: Make sure that the VFD is properly ventilated to prevent overheating. Ensure that the ventilation fans are clean and operational.

  5. Check the power supply: Ensure that the power supply voltage and frequency are within the specified range. An improper power supply can cause damage to the VFD.

  6. Check the capacitors: Inspect the capacitors for any signs of bulging or leaking. Faulty capacitors can cause damage to the VFD.

  7. Regularly check for errors: Check the VFD display for any error messages or fault codes. Address any issues promptly to prevent further damage.

  8. Follow the manufacturer's recommendations: Follow the manufacturer's recommended maintenance schedule and procedures to ensure proper operation of the VFD.

By following these steps, you can ensure that your VFD remains in good working condition and performs optimally.